Lowell MI House Tour – "Tightest Home around?"

Sam Pobst has offered to host a LEED for Homes meeting and tour at his house under construction.

Sam is targeting a LEED Platinum House. He has incorporated many very efficient features. In fact, the recent blower door test came in at “0.26 ACH, the lowest reading the Green Rater, Mike Holcomb has ever had. ”

This house attempted Passive Haus certification but fell short. Many lessons are to be learned as to why it was not achieved.

MARK YOUR CALENDER if you want to see this stellar construction in process:

Date: Friday, February 3, 2012
Time: 10 am – 12 pm
Address & Info:

13691 Beckwith Drive NE

Lowell, MI 49331

616-648-7493

Follow the project here http://sumacgrove.blogspot.com/

Highlights from Energy Star Version 3, Revision 05.

Revision 05 of the Version 3 guidelines has now been posted to the ENERGY STAR website. Partners are
permitted to use this Revision immediately, at their discretion, but must apply this Revision to all homes permitted
on or after March 15, 2012.

As part of this Revision, all major program documents have been updated. A Revision 05 Version Tracking Document, containing all of the specific changes in this Revision, has also been created. EPA strongly encourages partners to review these documents. The most substantial updates are summarized below:

Thermal Enclosure System Rater Checklist
 A new alternative to meeting 2009 IECC insulation requirements has been provided for homes that achieve ≤ 50% of the infiltration rate defined in the ENERGY STAR Reference Design.
 The timeline for complying with the minimum insulation levels required at attic eaves has been extended. In the interim, homes with space constraints are permitted to meet less stringent levels.
 Drywall adhesive (but not other construction adhesives) may now be used to seal drywall to top plates.
 Foam sealant may now be used in place of caulk to seal sill plates to foundations or sub-floors. Note that a foam gasket is still also required beneath the sill plate if resting atop concrete or masonry and adjacent to conditioned space.
 Batts that completely fill floor cavities enclosed on all six sides may be used, even when compression occurs due to excess insulation, as long as the R-value of the batts has been appropriately assessed based on manufacturer guidance and the only defect preventing the insulation from achieving the
required installation grade is the compression caused by the excess insulation. This policy replaces the
list of specific permutations of R-values and cavity depths that are permitted to be used.
 The methodology for evaluating compliance with the reduced thermal bridging requirements for mass
walls that are not part of a passive solar design (e.g., CMU block or log home enclosure) has been
clarified.

HVAC System Quality Installation Contractor Checklist
 Until credentials are available specifically for heating, cooling, and ventilation system designers, either the builder (or a firm or HERS Rater hired by the builder) or the credentialed HVAC contractor (or a firm or HERS Rater hired by the credentialed contractor) are permitted to design such systems and to complete Sections 1 through 5 of the Checklist. As always, the designer must comply with applicable codes and laws that regulate HVAC designers and HVAC designs. In all cases, Sections 6 through 12 of the Checklist may only be completed by a credentialed HVAC contractor.
 If there are no forced-air heating or cooling systems in the home, then Section 1 is the only section of the Checklist that must be completed. This is true even in such homes that use a forced-air ventilation system, because ASHRAE 62.2-2010 does not prescribe room-level duct design requirements for the ventilation system.
HVAC System Quality Installation Rater Checklist
 The maximum total Rater-measured duct leakage limit has been increased to 8 CFM25 per 100 square feet of conditioned floor area for all homes.
 Because the Checklist already limits total duct leakage, the mandatory requirement to seal and inspect duct boots has been removed. This change simply allows partners to use their judgment to determine when to seal duct boots to floors, walls, and ceilings to meet the total duct leakage limit.
 The method for performing bedroom pressure balancing tests has been clarified to require that all bedroom doors be closed and all air handlers be operating.
 The sone limits for multispeed ventilation and exhaust fans have been clarified by requiring that they be met when producing no less than the minimum airflow rate required.
 A footnote has been added to Item 2.7 and 2.8, which relate to balancing, to indicate that these
requirements do not apply to ventilation ducts

Energy Star Updates can be found at http://www.energystar.gov/index.cfm?c=bldrs_lenders_raters.nh_v3_policy_changes_clarifications

10 green building predictions for 2012

Earth Advantage Institute, a fellow nonprofit green building resource and LEED for Homes provider that has certified more than 12,000 homes, announced its annual prediction of 10 green building trends to watch in 2012 in as press release. seconds such predictions and puts in some of our own thoughts. 

The trends from a boom in certified multi-family construction to the advent of consumer friendly home energy technology.

  1. “Urban density. Millennials and boomers alike are choosing to live in the city where they can be closer to cultural activity, mass transit, more sustainable lifestyles, and other like-minded people, and builders must create more living space.  Builders are getting creative in gaining more living space through the construction of accessory dwelling units.”
  2. “Green multifamily homes. Earth Advantage Institute has seen a large spike in Northwest multifamily building certifications this past year, hinting that we might see a rise in certifications in 2012 as well.” has seen large spike in certified green projects for multifamily developments across the Midwest/
  3. “Energy upgrades start to drive home remodels. Builders and remodelers who are plugged into changing consumer preferences (smaller homes, reduced energy bills) have been able to capitalize on energy upgrade work.”
  4. “Deployment and testing of new materials. Although architects and builders are eager to try to new energy-saving materials and systems, these products require significant testing to ensure that the materials and benefits will last the life of the building and to avoid litigation.”
  5. “Consumer friendly home energy tracking devices. The introduction of the Apple-like Nest Learning Thermostat, and Belkin’s Conserve Insight energy use monitor that tracks energy use by appliance, are two of many sensor-based energy and water monitoring products for the home that are easy to use and help save money. Large electronics players like Fujitsu and Intel are also developing products, among others.”
  6. “Energy education for commercial tenants. The growing adoption of commercial building energy disclosure (New York; Washington, D.C.; San Francisco; Seattle; Austin) has building owners/operators and utilities seeking effective ways to educate tenants on saving energy.”
  7. “Transparency in home marketing. Builders, remodelers, and real estate professionals who can clearly educate their clients about the benefits and features of energy efficient, green homes will be those who earn the buyers’ confidence.”
  8. “More accurate appraisals. The ability for sellers and buyers to ask their banks for a green-certified appraiser means that the lending community will be open to the idea of the additional value and ROI offered by new certified homes and remodels.” – This is something or director is facing now. Attempting to get a proper appraisal for a moderate green home retrofit – you can learn more at http://grandrapidsgreenhomeretrofit.blogspot.com/
  9. “Broader adoption of residential energy ratings (and certifications!) for homes. Energy labeling systems are appearing in many states, offering estimates of a home’s energy consumption for homebuyers and homeowners.”
  10. Smart grid-compatible high-performance homes. Increasing numbers of home appliances are gaining the ability to monitor and report their own usage and to increase or decrease their electricity usage by remote command.

By Mary Beth Nevulis, HousingZone Contributing Editor

January 18, 2012

Chicago North Shore Home Earns LEED Platinum

Glencoe, IL LEED Platinum exteriorA Glencoe, IL home has just been awarded a Platinum rating by the United States Green Building Council (USGBC) LEED for Homes program, the highest level possible. The house is only the second new-construction LEED Platinum home in the State of Illinois and the first LEED Platinum home on the North Shore. View the LEED Project Snapshot

The Washington Avenue home was designed by Nathan Kipnis, AIA of Kipnis Architecture + Planning of Evanston and built by Scott Simpson Builders of Northbrook. Owners Barry and Natalie Slotnick moved into the house in April of 2011 with their two young children.
Glencoe, IL LEED Platinum rooflineThis home is unique in its commitment to staying within the aesthetic of the surrounding community while implementing a wide range of green goals. It’s one of the few LEED homes to take a non-modernist approach to its exterior, as well as being informed by traditional low-impact building philosophies. The home is classic in its style, form and proportions, yet modern in its use of materials, colors and systems. Green features include passive, natural ventilation; passive solar heating and cooling; water-efficient indoor plumbing fixtures including a waterless urinal; low and no-VOC finishes and fixtures; standing seam metal roofing; cement fiberboard siding; and prefabricated framing.

Architect Kipnis states, “The house was built for 40% of the cost of the first LEED Platinum home in Illinois and in a style that appeals to a much wider cross section of the public. While these homes can be thought of as pioneering efforts, if the goal is to engage the public then the design should be contextual to neighborhood and not be aesthetically shocking.  The Slotnick’s home is a perfect example of this.”

Glencoe, IL LEED Platinum interior

LEED for Homes is a voluntary, third-party certification program developed by residential experts and experienced builders. LEED promotes the design and construction of high performance green homes, and encourages the adoption of sustainable practices throughout the building industry.

Download the LEED Project Snapshot

Contacts:
Barry Slotnick – 847-875-4920; bslotnick@varisport.com
Nathan Kipnis – 847-864-9650; nkipnis@kipnisarch.com

Quick LEED for Homes count

There are 16,194 LEED for Homes certified units in the U.S as Jan 9th. 537 have been completed by . That is about 4% of the projects!